Products ¡ú
Lan Cable ¡úLan Cable CAT 5 |
|
|
|
|
Product Description |
Application |
| Rated temperature:60¡æ,75¡æ |
10 Base-T |
| Bare solid of stranded copper conductor |
100 Base-T4 |
|
Colour-coded PE insulation |
100 Base-TX |
| Rip cord(optional) |
100VG-AnyLAN |
| PVC or LSZH jacket |
155 Mbps ATM |
Flammadbility Grade:
CMX,CM,MP,CMG,MPG,CMR,MPR |
622 Mbps ATM |
|
| |
|
Cable Construction(CAT 5) |
|
Part No. |
Construction |
Conductor
Dimension
mm |
Core
Dimension
mm |
No. of
Pairs |
Shielding |
Nom O.D.
mm |
|
S1100-U-4 |
UTP |
0.51 |
0.91 |
4 |
- |
5.1 |
|
S1100-U-25 |
UTP |
0.51 |
0.91 |
25 |
- |
12.5 |
|
S1100-F-4 |
FTP |
0.53 |
1.00 |
4 |
Al Foil |
6.3 |
|
S1100-S-4 |
S-FTP |
0.53 |
1.00 |
4 |
Al foil+Cu Braiding |
6.6 |
|
S1100-4 |
Undercarpet |
0.51 |
0.91 |
4 |
- |
30*2.7 |
|
S1100-B-U |
Bundled UTP
|
0.51
|
0.93 |
2*4
|
- |
12*6.0 |
Bundled UTP |
0.51 |
0.93 |
4*4 |
13.7 |
Bundled UTP |
0.51 |
0.93 |
6*4 |
16.5 |
Bundled UTP |
0.51 |
0.93 |
8*4 |
18.3 |
|
| |
|
Electrical Characteristics(CAT 5) |
|
Frequency
Mhz |
Impedance
ohm |
SRL
dB |
Attenuation
dB/100m |
Next
Worst Pair
dB |
Next
Power Sum
dB |
|
0.772 |
100¡À15 |
12.0 |
2.2 |
43.0 |
43.0 |
|
1.0 |
12.0 |
2.6 |
41.3 |
41.3 |
|
4.0 |
12.0 |
5.6 |
32.3 |
32.3 |
|
8.0 |
12.0 |
8.5 |
27.8 |
27.8 |
|
10.0 |
12.0 |
9.7 |
26.3 |
26.3 |
|
16.0 |
10.0 |
13.1 |
23.3 |
23.3 |
|
| |
| Cable Construction(Patch Cable CAT 5-AWG 24) |
|
Part No. |
Construction |
Conductor
Dimension
mm |
Core
Dimension
mm |
No. of
Pairs |
Shielding |
Nom O.D.
mm |
|
S1100-U-4-24 |
Patch UTP #24 |
7/0.2 |
0.98 |
4 |
- |
5.5 |
|
| |
| Electrical Characteristics(Patch Cable CAT 5-AWG 24) |
|
Frequency
Mhz |
Impedance
ohm |
SRL
dB |
Attenuation
dB/100m |
Next
Worst Pair
dB |
Next
Power Sum
dB |
Elfext
Worst Pair
dB |
Nominal
Velocity
Propagation |
|
0.772 |
100¡À15 |
16.7 |
2.2 |
64.0 |
64.0 |
63.0 |
0.65 |
|
1.0 |
17.0 |
2.4 |
62.3 |
62.3 |
60.8 |
|
4.0 |
18.8 |
4.9 |
53.3 |
53.3 |
48.7 |
|
8.0 |
19.7 |
6.9 |
48.8 |
48.8 |
42.7 |
|
10.0 |
20.0 |
7.8 |
47.3 |
44.3 |
40.8 |
|
16.0 |
20.0 |
9.9 |
44.3 |
42.8 |
36.7 |
|
20.0 |
20.0 |
11.1 |
42.8 |
47.3 |
34.7 |
|
25.0 |
19.3 |
12.5 |
41.3 |
41.3 |
32.8 |
|
31.25 |
18.6 |
14.1 |
39.9 |
39.9 |
30.9 |
|
62.5 |
16.5 |
20.4 |
35.4 |
35.4 |
24.8 |
|
100.0 |
15.1 |
26.4 |
32.3 |
32.3 |
20.8 |
|
| |
| Cable Construction(Patch Cable CAT 5-AWG 26) |
|
Part No. |
Construction |
Conductor
Dimension
mm |
Core
Dimension
mm |
No. of
Pairs |
Shielding |
Nom O.D.
mm |
|
S1100-U-4-26 |
Patch UTP #26 |
7/0.16 |
0.84 |
4 |
Nil |
4.9 |
|
S1100-F-4-26 |
Patch FTP #26 |
7/0.16 |
0.86 |
4 |
Al-Foil |
5.1 |
|
S1100-S-4-26 |
Patch S-FTP #26 |
7/0.16 |
0.86 |
4 |
Al Foil+Cu Braiding |
5.6 |
|
| |
| Electrical Characteristics(Patch Cable CAT 5-AWG 26) |
|
Frequency
Mhz |
Impedance
ohm |
SRL
dB |
Attenuation
dB/100m |
Next
Worst Pair
dB |
Next
Power Sum
dB |
Elfext
Worst Pair
dB |
Nominal
Velocity
Propagation |
|
0.772 |
100¡À15 |
16.7 |
2.7 |
64.0 |
64.0 |
63.0 |
0.65 |
|
1.0 |
17.0 |
3.1 |
62.3 |
62.3 |
60.8 |
|
4.0 |
18.8 |
6.1 |
53.3 |
53.3 |
48.7 |
|
8.0 |
19.7 |
8.6 |
48.8 |
48.8 |
42.7 |
|
10.0 |
20.0 |
9.7 |
47.3 |
47.3 |
40.8 |
|
16.0 |
20.0 |
12.4 |
44.3 |
44.3 |
36.7 |
|
20.0 |
20.0 |
13.9 |
42.8 |
42.8 |
34.7 |
|
25.0 |
19.3 |
15.6 |
41.3 |
41.3 |
32.8 |
|
31.25 |
18.6 |
17.6 |
39.9 |
39.9 |
30.9 |
|
62.5 |
16.5 |
25.5 |
35.4 |
35.4 |
24.8 |
|
100.0 |
15.1 |
33.0 |
32.3 |
32.3 |
20.8 |
|
*BC- Bare Copper
*TC-Tinned Copper |